DC type dynamic strain amplifier DAS-406B

 
 
 

Untuk memesan, silahkan tekan tombol ORDER. Anda bisa memesan barang secara Online.

 

Anda juga bisa memesan via telephone. Silakan hubungi sales consultant, Hotline kami di, 0878 7800 3233 , 0821 1170 1076 sales Consultant kami akan menjelaskan detail produk dan harga terbaru. atau email ke alamat sales@rajaloadcell.com

FEATURES

  • DC ~ 200 kHz Characteristics in the frequency
  • Standard equivalent strain amplifier with four digit digital switch setting
  • 3 1/2 digit digital monitor

 

SPECIFICATIONS

Measuring point 1 point/1 unit
Applicable gage resistance 60 Ω ~ 1kΩ
Gage factor 2.00
Bridge power supply DC2 V(DC1, 4, 10 V Changeable to)
with remote sensing function(50 mA or less)
Balancing adjustable range Resistance section Approx. ±1 %
(Gage resistance  120 Ω Approx. ±5 000x10-6 in strain)
Balancing adjustable method Auto balance,
Auto balance time Approx.1 s,
Accuracy ±0.1 %F.S.
Sensitivity 0.5 V output at the input of 100 x 10-6 in strain
(When bridge power supply is DC2 V)
Output MONITOR ±10 V, ±5 mA (Load resistance2 kΩor more)
OUTPUT ±10 V, ±30 mA (Load resistance 330 Ωor more)
Output resistance10 Ω or less
Output capacitive load0.1 μF or less
Non-linearity ±0.01 % F.S.
Standard equivalent strain(CAL) Set with digital switch
±1 ~ ±9 999x10-6 in strain ,
Accuracy ±0.2 %F.S. or less at each point
Sensitivity adjustable range(ATT) 1, 1/2, 1/5, 1/10, 1/20, 1/50, 1/100, 0
Accuracy ±0.2 %F.S. at each point
GAIN volumu valiable range
1 to 1/2.5 times continuous vary(VAR)
Frequency response range DC to 200 kHz +1 dB, -3 dB (Filter at W/B)
Low-pass filter 10 Hz, 100 Hz, 1 kHz, 10 kHz, W/B Third bessel type
S/N ratio 46 dBp-p(ATT=1) with W/B condition
55 dBp-p with 10 Hz to 10 kHz
Display Output voltage display 0.00 to ±10.00
Digital display (Green LED)
Sampling Approx.4 times/s
0.00 or -0.00 flashes when output voltage is in non-linearity zone
Temperature efficient Zero shift ±0.1x10-6 in strain / ℃
Sensitivity variation ±0.01 %F.S./℃
Efficient due to time Zero shift ±5x10-6 in strain / 8 h
Sensitivity variation ±0.05 %F.S./8 h
Efficient due to power supply Zero shift ±1x10-6 in strain / variation of power supply voltage within ±10 %
Sensitivity valliation ±0.01 %F.S.
/variation of power supply voltage within±10 %
Operating temp./humidity range Temperature :-10 ℃ to 50 ℃, Humidity 85 %RHor less (Non condensing)
Power supply voltage AC100 V±10 V, DC12 V 50/60 Hz
Power consumption Approx. 10 VA(at AC100 V), Options DC12 V Approx. 0.8 A
Outline dimensions(WxHxD) 42 mmx176 mmx284.4 mm(excludes protruding parts)
Weight Approx. 1.5 kg