DC type dynamic strain amplifier DAS-406B

 
 
 

Untuk memesan, silahkan tekan tombol ORDER. Anda bisa memesan barang secara Online.

 

Anda juga bisa memesan via telephone. Silakan hubungi sales consultant, Hotline kami di, 021 8611 259 sales Consultant kami akan menjelaskan detail produk dan harga terbaru. atau email ke alamat sales@rajaloadcell.com

FEATURES

  • DC ~ 200 kHz Characteristics in the frequency
  • Standard equivalent strain amplifier with four digit digital switch setting
  • 3 1/2 digit digital monitor

 

SPECIFICATIONS

Measuring point 1 point/1 unit
Applicable gage resistance 60 Ω ~ 1kΩ
Gage factor 2.00
Bridge power supply DC2 V(DC1, 4, 10 V Changeable to)
with remote sensing function(50 mA or less)
Balancing adjustable range Resistance section Approx. ±1 %
(Gage resistance  120 Ω Approx. ±5 000x10-6 in strain)
Balancing adjustable method Auto balance,
Auto balance time Approx.1 s,
Accuracy ±0.1 %F.S.
Sensitivity 0.5 V output at the input of 100 x 10-6 in strain
(When bridge power supply is DC2 V)
Output MONITOR ±10 V, ±5 mA (Load resistance2 kΩor more)
OUTPUT ±10 V, ±30 mA (Load resistance 330 Ωor more)
Output resistance10 Ω or less
Output capacitive load0.1 μF or less
Non-linearity ±0.01 % F.S.
Standard equivalent strain(CAL) Set with digital switch
±1 ~ ±9 999x10-6 in strain ,
Accuracy ±0.2 %F.S. or less at each point
Sensitivity adjustable range(ATT) 1, 1/2, 1/5, 1/10, 1/20, 1/50, 1/100, 0
Accuracy ±0.2 %F.S. at each point
GAIN volumu valiable range
1 to 1/2.5 times continuous vary(VAR)
Frequency response range DC to 200 kHz +1 dB, -3 dB (Filter at W/B)
Low-pass filter 10 Hz, 100 Hz, 1 kHz, 10 kHz, W/B Third bessel type
S/N ratio 46 dBp-p(ATT=1) with W/B condition
55 dBp-p with 10 Hz to 10 kHz
Display Output voltage display 0.00 to ±10.00
Digital display (Green LED)
Sampling Approx.4 times/s
0.00 or -0.00 flashes when output voltage is in non-linearity zone
Temperature efficient Zero shift ±0.1x10-6 in strain / ℃
Sensitivity variation ±0.01 %F.S./℃
Efficient due to time Zero shift ±5x10-6 in strain / 8 h
Sensitivity variation ±0.05 %F.S./8 h
Efficient due to power supply Zero shift ±1x10-6 in strain / variation of power supply voltage within ±10 %
Sensitivity valliation ±0.01 %F.S.
/variation of power supply voltage within±10 %
Operating temp./humidity range Temperature :-10 ℃ to 50 ℃, Humidity 85 %RHor less (Non condensing)
Power supply voltage AC100 V±10 V, DC12 V 50/60 Hz
Power consumption Approx. 10 VA(at AC100 V), Options DC12 V Approx. 0.8 A
Outline dimensions(WxHxD) 42 mmx176 mmx284.4 mm(excludes protruding parts)
Weight Approx. 1.5 kg